Beta Amyloid Peptide: Beta Amyloid Peptide: Research Paper : Test-retest reproducibility of dopamine transporter density measured with [ 18 F]FP-CIT PET in patients with essential tremor and Parkinson's disease

Beta Amyloid Peptide: Research Paper : Test-retest reproducibility of dopamine transporter density measured with [ 18 F]FP-CIT PET in patients with essential tremor and Parkinson's disease

Test-retest reproducibility of dopamine transporter density measured with [ 18 F]FP-CIT PET in patients with essential tremor and Parkinson's disease

Abstract

Objective: 18F-labeled fluoropropyl-carbomethoxylodopropyl-nor-ß-tropane ([18F]FP-CIT) positron emission tomography (PET) is a useful tool for evaluating disease progression in Parkinson's disease (PD) patients. We evaluated the test-retest reproducibility of [18F]FP-CIT PET measures in essential tremor (ET) and PD patients.

Methods: Fifteen ET (68.9 ± 6.6 years) and 10 PD patients (70.5 ± 6.3 years; Hoehn and Yahr stage, 2.3 ± 0.8) underwent two [18F]FP-CIT PET/CT scans with an interval of 48 ± 7 day. For both the test and retest studies, standardized uptake value ratios were estimated for 90-min and 3-h acquisitions for the caudate, anterior putamen, and posterior putamen using T1-MRI-based normalization (automatic) and fixed-VOI (manual) methods, with the occipital lobe as a reference. Reproducibility was evaluated by the bias, variability, percent test-retest, within-subject coefficient of variation, repeatability coefficient, and intraclass correlation coefficient (ICC).

Results: Reproducibility was excellent, with low variability (ET: 6.99-8.02%, PD: 3.51-6.94%) and high reliability (ICC; ET: 0.88-0.96, PD: 0.98-0.99). The ET group showed higher variability and lower ICCs than the PD group. The variability in the 90-min images (ET: 7.85-8.59%, PD: 1.52-2.75%) was comparable to that in the 3-h images (ET: 6.99-8.02%, PD: 3.51-6.94%). There were no differences in variability among the subregions in the ET group. In the PD group, the variability was high in the posterior putamen (automatic method: 6.94%, manual method: 11.80%). The test-retest variability and ICCs were similar for the manual and automatic methods.

Conclusion: [18F]FP-CIT PET is reproducible for the quantitative measurement of DAT binding in both ET and PD individuals, independent of the acquisition time or analysis method. Also, the automatic method is more suitable for evaluating early loss of DAT binding in patients with PD.

Keywords: Essential tremor; Parkinson's disease; Reliability; Reproducibility; [18F]FP-CIT PET/CT


This article originally appeared in the "https://pubmed.ncbi.nlm.nih.gov/33387281/" and has their copyrights. We do not claim copyright on the content. This information is for research purposes only. This Blog is made available by publishers for educational purposes only as well as to give you general information and a general understanding , not to provide specific advice. By using this blog site you understand that there is no client relationship between you and the Blog publisher. The Blog should not be used as a substitute for competent research advice.  